EPD Annual Follow-Up: When Manufacturers Need an Update

Construction material samples and measurement tools prepared for an EPD data review at a manufacturing facility.
Construction material samples and measurement tools prepared for an EPD data review at a manufacturing facility.

An Environmental Product Declaration (EPD) needs attention after publication. A factory may change suppliers, revise a formulation or alter its energy supply while the declaration still shows a future expiry date. Manufacturers need a process for deciding whether those changes affect the information customers receive.

This guide addresses the International EPD System. Its annual follow-up and update criteria should not be assumed to apply identically across every programme operator.

Validity and maintenance are different

The International EPD System’s validity guidance describes a normal five-year validity period and changes that can require an earlier update. An unexpired date alone therefore does not settle whether the declaration remains representative.

Start by recording the applicable Product Category Rules (PCR) and General Programme Instructions (GPI) versions. The operator’s GPI guidance states that surveillance of an existing EPD follows the versions used for its verification. A newly published rulebook does not automatically invalidate an existing declaration.

Review annually and when important changes occur

In its 11 December 2025 notice, EPD International reiterates that owners must implement internal follow-up at least annually, using the latest version date as the reference. The review frequency must also capture significant developments. Treat the annual review as a minimum checkpoint and assess important changes when they arise.

That notice also identifies errors and substantial changes in product, composition or additional declared information as reasons for updating and re-verifying. A new manufacturing location or changed product lifespan can matter even before a percentage calculation is considered.

Understand the 10% threshold

Under GPI 5.0.1, Section 6.8.1, an increase reaching or exceeding 10% in any declared LCA-based indicator, calculated across the life-cycle stages included, requires an update and re-verification. Module D is excluded from that aggregation. For climate change, the threshold concerns GWP-total rather than its individual sub-indicators.

Ask the LCA practitioner to calculate the comparison consistently with the applicable rules. Avoid screening only the headline carbon figure: the test covers other declared indicators too. Equally, a change below the threshold does not resolve a separate error or substantial product-information change.

Prepare a useful review pack

The following checklist is a practical way to organise evidence for the review, rather than an additional programme requirement:

  • Product definition: current formulations, specifications, product variants and manufacturing locations, with effective dates for changes.
  • Production records: output, energy and fuel consumption, water use, waste and yield information for a clearly identified period.
  • Supply-chain evidence: supplier changes, transport information and revised supporting declarations or datasets.
  • Previous assessment: the published EPD, underlying LCA report, model version, assumptions and verification records.
  • Change log: what changed, when, who confirmed it and which evidence supports the explanation.

Keep units, reporting periods and product boundaries visible. A larger factory-wide electricity total might reflect higher production rather than a change per declared unit. Separate those explanations before asking for a technical decision.

Turn the review into a documented decision

Use a simple workflow:

  1. Assign responsibility. Appoint an internal EPD coordinator and identify contacts in production, procurement and product development.
  2. Collect changes. Compare the current evidence with the basis of the published declaration. Record missing information explicitly.
  3. Assess significance. Ask the LCA practitioner which inputs need recalculation and which descriptive sections need attention.
  4. Record the outcome. Explain why the existing declaration remains representative or what needs updating. Set owners and dates for unresolved actions.
  5. Control distribution. After an update is published, review website downloads, sales materials and customer-facing references for superseded versions.

The operator provides an example internal follow-up report. It supports documentation; it does not add requirements beyond the GPI.

Where an update is necessary, involve the verifier. GPI Section 8.4.9 distinguishes substantive updates, which require re-verification, from purely editorial corrections. Do not assume that an updated document automatically receives a new five-year period.

Frequently asked questions

Does annual follow-up mean publishing a new EPD every year?

No. The review determines whether an update is needed. Keep a documented conclusion even when no relevant change is identified.

Can the manufacturer conduct the follow-up internally?

Yes. GPI Section 8.4.8 allows company-led follow-up or continuing verifier involvement. The records must be available on request.

Where should a manufacturer begin?

Gather the current EPD, applicable rules, previous review record and a list of production or supplier changes. Agree the assessment scope before commissioning calculations.

Discuss your EPD maintenance needs

ERKE provides EPD consultancy and LCA consulting. Contact ERKE to discuss your declaration, available evidence and the support needed for its next review.